View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0009062 | ardour | bugs | public | 2022-11-01 17:58 | 2022-11-02 18:37 |
Reporter | sollapse | Assigned To | x42 | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Platform | Microsoft | OS | Windows | OS Version | 11 |
Product Version | 7.0 | ||||
Summary | 0009062: Motorized fade setting not saved with session. | ||||
Description | I've noticed that I have to re-enable the Motorized option on opening a session. This causes assignment to be lost for automation controllers. | ||||
Steps To Reproduce | Open a session, add a Generic MIDI controller and select Motorized. Assign parameters with any MIDI control. Save the session then reopen. Motorized will be disabled. | ||||
Tags | No tags attached. | ||||
|
*Meant to say motorized option instead of fade. |
|
Are you perhaps using an AKAI_MPKmini preset (or a custom preset that explicitly sets motorized = false? |
|
Fixed in Ardour 7.0-200-g6813884857 |
|
It's a custom MPK225 mapping file. I now see there is a setting for motorized under bank in the MPKmini map. |
Date Modified | Username | Field | Change |
---|---|---|---|
2022-11-01 17:58 | sollapse | New Issue | |
2022-11-01 18:00 | sollapse | Note Added: 0026815 | |
2022-11-02 16:22 | x42 | Note Added: 0026837 | |
2022-11-02 16:48 | x42 | Assigned To | => x42 |
2022-11-02 16:48 | x42 | Status | new => resolved |
2022-11-02 16:48 | x42 | Resolution | open => fixed |
2022-11-02 16:48 | x42 | Note Added: 0026840 | |
2022-11-02 18:37 | sollapse | Note Added: 0026843 |