View Issue Details

IDProjectCategoryView StatusLast Update
0001337ardourbugspublic2009-07-05 20:43
Reporterthorwil Assigned To 
PrioritynormalSeverityminorReproducibilityalways
Status acknowledgedResolutionopen 
Summary0001337: Input/Output popup menu connection items don't reflect current state in some cases
DescriptionTake for example a mono channel, where the options below "Edit" and "Disconnect" are "In 1" and "In 2". After selecting "Edit" and hooking up both inputs in the dialog, the 2 items are unchecked, making it look like no such connection are active.

The Popup items should be checked/unchecked to reflect the current state at all times.

One can easily switch from both/all connected to only one channel via the popup items, but not back again. To solve this issue, it should be possible to enable more than 1 of the items by use of ctrl-clicking, to also maintain the current fast selection ability without having to uncheck items manualy.

Closely related: the naming of the items is confusing, as the user has to make the mental connection between things like "In 1" and "alsa_pcm:capture_1".
TagsNo tags attached.

Activities

paul

2006-12-20 21:16

administrator   ~0002945

no, there is a more central issue here.

"In 1" is *not* alsa_pcm:capture_1. Its a "Connection" object called "In 1" that just happens to include a single port with a connection to alsa_pcm:capture_1.

There is no Connection editor any more, so this point is somewhat lost. The checking of the items in the lower part of the menu indicate "This I/O is using this specific Connection", which is not the same as "This I/O is connected to alsa_pcm:foobar_N". If no items are checked, the IO object wasn't hooked up via a specific Connection, but by manual selection of destinations/sources.

So, I think this is just a documentation/labelling issue. Agree?

thorwil

2006-12-21 17:02

reporter   ~0002947

I wasn't able to build a correct mental model. Asking in #ardour while Paul wasn't around revealed nobody was sure about the nature of what appears in the popups. Aside from that, yes I guess it's 'just' documentation/labeling.

This stuff should be rethought when it's time for the routing matrix.

seablade

2009-07-05 02:21

manager   ~0006285

Is this still an issue in recent versions of Ardour? I wasn't able to follow the comments precisely, and I am not sure if it still even applies without the connection editor.

thorwil

2009-07-05 08:43

reporter   ~0006338

It still seems to be the same.

It still doesn't make the tiniest bit of sense to me.

seablade

2009-07-05 20:43

manager   ~0006351

Ok removing this from feedback at least since it has been given. Still not completely following the comments, maybe A3 will improve on this though with the revamped connections.

Issue History

Date Modified Username Field Change
2006-11-22 13:00 thorwil New Issue
2006-12-20 21:16 paul Note Added: 0002945
2006-12-20 21:16 paul Status new => feedback
2006-12-21 17:02 thorwil Note Added: 0002947
2009-07-05 02:21 seablade Note Added: 0006285
2009-07-05 02:21 seablade Description Updated
2009-07-05 08:43 thorwil Note Added: 0006338
2009-07-05 20:43 seablade Note Added: 0006351
2009-07-05 20:43 seablade Status feedback => acknowledged