Summary0005071: MIDI fader and output connection confused after removal of synth plugin
Description1. create a new session
2. add a new MIDI track
3. the fader in the mixer window scales 0-127
4. add eg. the Calf FluidSynth plugin pre-fader
5. the fader scale depends on the metering point:
 in: 0-127
 pre, post: 4-50 (I guess the minus sign is left off to gain screen space)
 out,custom: 0-127 and 4-50 (three indicator strips)
6. delete the synth plugin
7. the out and custom metering points still offer three indicator strips with combined scales, and the track output still connects to the master bus stereo inputs, which shouldn't be possible anymore.
Additional InformationSVN revision: 13053
TagsNo tags attached.

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2012-08-07 11:08 wferi New Issue
2012-09-01 11:35 cth103 cost => 0.00
2012-09-01 11:35 cth103 Target Version => 3.0